iPhone 6 Not Boot after Meson and Cumulus Reballing

Alexandre Isaac 02/13/2019

Hi, I have 2 iPhone 6 taht won't boot anymore, just after I reballed Meson and Cumulus because of touch disease. They stay stuck on 0.20A, then switch off after a while. No idea ?
rewa
Answers
rewa

REWA

02/18/2019

CPU has been pseudo soldered when replacing the touch IC. You need to re-solder CPU.